top of page
海报1.jpg

Product Feature

left_banner0
left_banner2

Working Methods

Since 1997, NSF certified, to deliver flawless products to all customers.

ITiGER Fitting is more fast and easy to connect into tube as push-fit type and is possible to maintain and repair more stable. It is possible to re-use tube because tube scratch by collets is small. ITiGER fitting can prevent leakage as following working procedure and it is easy to connect and separate.

How to connect

Step 1.

  • Cut the part of the tube to be inserted into the fitting to plane the end.

  • Make sure to use a clean tube without any foreign material or cracks.

Step 2.

  • When inserting the tube, remove any obstructions before fully inserting the tube. Make sure the tube is fully inserted.

  • Inserting the tube into the fitting only takes moderate force. The tube or fitting should not be scratched or damaged in the process, as this is the main cause for water leaks later on.

Step 3.

  • To make sure that the fitting is properly connected to the tube, pull it once. After pulling, insert a spanner under the collet and push the tube into the fitting once more for a complete insertion.

Step 4.

  • When no play is desired for the fitting and tube, use our company's LC to eliminate the play of the fitting.

Step 5.

  • Make sure to completely eliminate pressure before disassembling the fitting.

  • When disassembling the tube, push the clip in direction of the main assembly and then pull the tube out for easy disassembling.

bottom of page